LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Hyundai >> 2010 >> Azera GLS >> Repair and Diagnosis >> Engine Mechanical >> Auxiliary Emission Control Systems >> Evaporative Emission Control System >> Repair procedures >> Inspection >> Notes
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Repair procedures: Inspection: Notes

  1. Disconnect the vacuum hose from the throttle body, and connect a vacuum pump to the vacuum hose.
  2. Check the following points when the engine is cold [engine coolant temperature 60°C (140°F) or below] and when it is warm [engine coolant temperature 80°C (176°F) or higher].

    When Engine Is Cold 

    VACUUM REFERENCE CHART - WHEN ENGINE IS COLD

    Engine operating condition Applied vacuum Result
    Idling 50 kPa (7.3 psi) Vacuum is held
    3,000 rpm

    When Engine Is Warm 

    VACUUM REFERENCE CHART - WHEN ENGINE IS WARM

    Engine operating condition Applied vacuum Result
    Idling 50 kPa (7.3 psi) Vacuum is held
    Within 3 minutes after engine start at 3,000 rpm Try to apply vacuum Vacuum is released
    After 3 minutes have passed after engine start at 3,000 rpm 50 kPa (7.3 psi) Vacuum will be held momentarily, after which, it will be released