MFI Control System: Injector: Inspection
- Measure the resistance of the injectors between the terminals using an ohmmeter.
Resistance
: 13~16Ω (at 20°C (68°F))
- If the resistance is not within specification, replace the injector.
Courtesy of HYUNDAI MOTOR CO.