Anti-Theft Function
- Arm function
Time specification
T1: 0.5sec.
T2: Max 2sec.
T3: 1.0+/-0.2sec.
- Disarm function
Time specification
T1, T2: 0.5+/-0.1 sec.
- Alarm function
- Time specification
T1: 27+/-2sec.
T2: 10+/-1 sec.
T3: 0.5+/-0.1 sec.
- New alarm occurs while the alarm is sounding.
- Disarmed with TX (Transmitter) while the alarm is sounding.
Courtesy of HYUNDAI MOTOR CO.
Time specification
T1, T2, T3: 0.5+/-0.1 sec.
- TX (Transmitter) lock button pressed when the door closed while the alarm is sounding.Fig 6: TX (Transmitter) Lock Button Pressed When Door Closed While The Alarm Is Sounding Timing Chart
Courtesy of HYUNDAI MOTOR CO.
Time specification
T1: 0.5sec.
T2: 1.0+/-0.2sec.
- TX (Transmitter) lock button pressed when the door opened while the alarm is sounding.
Courtesy of HYUNDAI MOTOR CO.
Time specification
T1: 0.5sec.
T2: 1.0+/-0.2sec.
- Disarmed after 30 sec when the ignition switch is turned on while the alarm is sounding.
- Start inhibit is "ON" regardless of door latch lock state.
- Battery is disconnected during the alarm state.
- Time specification