Electrical Specifications
GENERATOR
All Engines
Type Battery voltage sensing Rated output 13.5 V / 120 A Voltage regulator type Electronic built-in type Regulator setting voltage 14.4 ± 0.3 V Temperature compensated -10 ± 3 mV/°C