Component Testing: Sub-Switch
NOTE:
Sub-switch is incorporated into multifunction switch. If sub-switch is defective, multifunction switch assembly must be replaced.
Disconnect appropriate multifunction switch harness connector. Check continuity between appropriate switch terminals with switch in specified position. See SUB-SWITCH CONTINUITY . SeeFig 1 . If switch does not test as specified, replace multifunction switch.
SUB-SWITCH CONTINUITY
| Switch Position | Continuity Between Terminals No. |
|---|---|
| SET/COAST | 11 & 17 |
| RESUME/ACCEL | 11 & 18 |