September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Malfunction Threshold
A malfunction is detected if the following conditions are present after the engine has stopped and the vehicle condition has been turned to the OFF (LOCK) mode for at least 6 hours before restarting the engine:
| Temperature difference between each sensor values |
Malfunction judgment |
| ECT sensor 1 - ECT sensor 2 |
IAT sensor 2 - ECT sensor 2 |
ECT sensor 1 |
IAT sensor 2 |
ECT sensor 2 |
| Higher than 57 deg.F (32 deg.C) |
Higher than 57 deg.F (32 deg.C) |
Normal |
Normal |
Failure |
| From -43 deg.F (-24 deg.C) to 57 deg.F (32 deg.C) |
Failure |
Normal |
Normal |
| Lower than -43 deg.F (-24 deg.C) |
Failure |
Failure |
Normal |
| From -43 deg.F (-24 deg.C) to 57 deg.F (32 deg.C) |
Higher than 57 deg.F (32 deg.C) |
Normal |
Failure |
Normal |
| From -43 deg.F (-24 deg.C) to 57 deg.F (32 deg.C) |
Normal |
Normal |
Normal |
| Lower than -43 deg.F (-24 deg.C) |
Normal |
Failure |
Normal |
| Lower than -43 deg.F (-24 deg.C) |
Higher than 57 deg.F (32 deg.C) |
Failure |
Failure |
Normal |
| From -43 deg.F (-24 deg.C) to 57 deg.F (32 deg.C) |
Failure |
Normal |
Normal |
| Lower than -43 deg.F (-24 deg.C) |
Normal |
Normal |
Failure |
- When the IAT sensor 2 is normal 10 seconds after starting the engine, the IAT 2 sensor is used to detect malfunction in the IAT sensor 1.
| Temperature difference between each sensor values |
Malfunction judgment |
| IAT sensor 1- IAT sensor 2 |
ECT sensor 1 |
| Higher than 57 deg.F (32 deg.C) |
Failure |
| From -43 deg.F (-24 deg.C) to 57 deg.F (32 deg.C) |
Normal |
| Lower than -43 deg.F (-24 deg.C) |
Failure |