Malfunction Threshold

The temperature in the ATF temperature sensor deviates from the temperature in ECT sensor 2, less than -43 °F (-24 °C) or greater than 57 °F (32 °C)*.

*: Greater than 108 °F (60 °C) if engine block heater is equipped.