LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2012 >> Fit Base, Automatic Trans >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2012 HONDA >> Mode $06 Information By Test >> A/F Sensor (Bank 1)
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

A/F Sensor (Bank 1)

DTC P0134: Monitor ID $01: Test ID $80

OBD Monitor ID $01 Test ID $80 Unit and Scaling ID $11
DTC P0134
Test Description Check of A/F sensor "non-activation" time. See Test ID $81 and $82 for "non-activation" criteria.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.1 (sec.)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (sec.)
DTC P0134: Monitor ID $01: Test ID $82

OBD Monitor ID $01 Test ID $82 Unit and Scaling ID $0B
DTC P0134
Test Description Check of A/F sensor "non-activation" by monitoring the sensor cell voltage.
Store Timing Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.01 (V)
The lowest limit value: Output value (Decimal) x 0.01 (V)
The highest limit value: Output value (Decimal) x 0.01 (V)
DTC P2195: Monitor ID $01: Test ID $83

OBD Monitor ID $01 Test ID $83 Unit and Scaling ID $8D
DTC P2195
Test Description Check of the A/F sensor "too lean" by monitoring the A/F sensor signal.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.003906 (mA)
The lowest limit value: Output value (Decimal) x 0.003906 (mA)
The highest limit value: Not applicable
DTC P2A00: Monitor ID $01: Test ID $84

OBD Monitor ID $01 Test ID $84 Unit and Scaling ID $8D
DTC P2A00
Test Description Check of A/F sensor rationality by monitoring the sensor signal during fuel cut condition.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.003906 (mA)
The lowest limit value: Output value (Decimal) x 0.003906 (mA)
The highest limit value: Output value (Decimal) x 0.003906 (mA)
DTC P0133: Monitor ID $01: Test ID $85

OBD Monitor ID $01 Test ID $85 Unit and Scaling ID $01
DTC P0133
Test Description Response check of A/F sensor by monitoring the amplitude of filtered sensor signal during stable driving condition.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: No unit
The lowest limit value: No unit
The highest limit value: Not applicable
DTC P1172: Monitor ID $01: Test ID $86

OBD Monitor ID $01 Test ID $86 Unit and Scaling ID $8D
DTC P1172
Test Description Check of A/F sensor "out of range" by monitoring the sensor signal.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.003906 (mA)
The lowest limit value: Output value (Decimal) x 0.003906 (mA)
The highest limit value: Not applicable
DTC P0134: Monitor ID $01: Test ID $87

OBD Monitor ID $01 Test ID $87 Unit and Scaling ID $14
DTC P0134
Test Description Check of A/F sensor "non-activation" by monitoring the sensor element resistance during A/F feedback control.
Store Timing Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (W)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 1 (W)
DTC P0134: Monitor ID $01: Test ID $88

OBD Monitor ID $01 Test ID $88 Unit and Scaling ID $0B
DTC P0134
Test Description Check of A/F sensor "non-activation" by monitoring the sensor cell voltage during A/F feedback control.
Store Timing Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.01 (V)
The lowest limit value: Output value (Decimal) x 0.01 (V)
The highest limit value: Output value (Decimal) x 0.01 (V)
DTC P0133: Monitor ID $01: Test ID $89

OBD Monitor ID $01 Test ID $89 Unit and Scaling ID $01
DTC P0133
Test Description Response check of A/F sensor by monitoring the amplitude of filtered sensor signal during stable driving condition.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: No unit
The lowest limit value: No unit
The highest limit value: Not applicable