DTC P2770: Open in Torque Converter Clutch Solenoid Valve Circuit: General Description
The torque converter clutch solenoid valve switches the hydraulic circuit to engage/disengage the torque converter clutch. When the torque converter clutch solenoid valve is turned ON, hydraulic pressure is applied to the torque converter clutch. When the torque converter clutch solenoid valve is turned OFF, hydraulic pressure to the torque converter clutch is interrupted. The powertrain control module (PCM) commands the driver circuit to turn on the torque converter clutch solenoid valve. The circuit diagnoses malfunctions such as a circuit short or open, and sends back a return signal during the PCM's command. When the return signal does not match the PCM command, a malfunction is detected by the PCM. The malfunction is detected when the return signal does not match the PCM command to turn OFF the torque converter clutch solenoid valve, and a DTC is stored.