LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2007 >> Fit Base, Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating System >> Symptom Troubleshooting Index
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Symptom Troubleshooting Index

SYMPTOM TROUBLESHOOTING CHART

Symptom Diagnostic procedure Also check for
Blower motor runs, but one or more speeds are inoperative BLOWER MOTOR CIRCUIT TROUBLESHOOTING  (see )
  • Faulty blower resistor
  • Cleanliness and tightness of all connectors
Blower motor does not run at all BLOWER MOTOR CIRCUIT TROUBLESHOOTING  (see )
  • Blown fuse No. 5 (40 A) in the under-hood fuse/relay box, and No. 10 (7.5 A) in the under-dash fuse/relay box
  • Poor ground (G402, G403) (see GROUND TO COMPONENTS INDEX )
  • Cleanliness and tightness of all connectors
Blower motor runs with the fan switch off BLOWER MOTOR CIRCUIT TROUBLESHOOTING  (see ) Short in blower motor ground circuit