LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2005 >> Element EX, 2.4 YH2, Automatic >> Repair and Diagnosis >> Engine Performance >> Fuel Delivery >> Fuel And Emissions Systems >> How to Set Readiness Codes >> Evaporative Emission (EVAP) Control System Monitor and Readiness Code >> Procedure
September 30: LEMON manuals is back up on a temporary server! Slowness is possible

Evaporative Emission (EVAP) Control System Monitor and Readiness Code: Procedure

  1. Connect the HDS to the vehicle's data link connector (DLC).
  2. Start the engine.
  3. Select EVAP TEST in the INSPECTION MENU with the HDS, then select the FUNCTION TEST in the EVAP TEST MENU.
    • If they are normal, readiness is complete.
    • If they are not normal, go to the next step.
  4. Check for a Temporary DTC. If there is no DTC, one or more of the enable criteria were probably not met; repeat the procedure.