LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2003 >> Pilot EX >> Repair and Diagnosis >> General Information >> Specifications Index >> Common Specs & Procedures >> Starting System >> Starter >> Starter Service Specifications
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Starter Service Specifications

STARTER PERFORMANCE TEST SPECIFICATIONS

Application (1) Maximum Amps @ Minimum RPM
Starter 80 @ 2600
(1) Battery voltage must stay at 11.5 volts or more during test.
STARTER SPECIFICATIONS

Application Specification
Brush Length
Standard .62 -.64" (15.8- 16.2 mm)
Minimum .43" (11.0 mm)
Brush Spring Tension 3.53-3.97 lbs (15.7-17.7 N)
Commutator Diameter
Standard 1.102-1.106" (28.0-28.1 mm)
Minimum 1.083" (27.5 mm)
Commutator Mica Depth
Standard .016-.020" (.4-.5 mm)
Minimum .006" (.15 mm)
Commutator Runout
Standard .001" (.02 mm)
Minimum .002" (.05 mm)