Pilot Lamp
- Turn ignition on. With a jumper wire connect terminals 2 and 9 in the control unit connector. See Figure. If pilot lamp does not light, check for continuity between terminal 14 of control unit connector and terminal 8 of pilot lamp connector. See Fig 1.
- If there is no continuity, there is an open circuit in the wiring harness between pilot lamp and control unit. If there is continuity, check bulb. If defective, replace. If bulb is okay, circuit board or control unit is defective.
- If lamp lights in step 1, turn on the main switch. If pilot lamp does not light, control unit is defective. If lamp lights, circuits are okay.