LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> GMC >> 1991 >> Syclone V6-262 4.3L Turbo >> Repair and Diagnosis >> Heating and Air Conditioning >> Blower Motor Switch >> Service and Repair
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Blower Motor Switch: Service and Repair

Air Distribution System Component View:




Control Assembly:




Wiring Harness:




Cable:








REMOVE OR DISCONNECT

1. Negative battery cable.

2. Instrument panel center bezel.

3. Control assembly screws (71).

- Pull the control assembly (70) outward.

4. Vacuum harness (73).

5. Electrical connection (126).

6. Cables (67 and 72).

7. Control assembly (70).

8. Blower switch.


INSTALL OR CONNECT

1. Blower switch to the control assembly (70).

2. Cables (67 and 72).

3. Electrical connection (126).

4. Vacuum harness (73).

5. Control assembly (70) to the instrument panel.

6. Screws (71).

7. Instrument panel center bezel.

8. Negative battery cable.