October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Stator Test
- For 10SI series alternator, measure resistance between stator leads. See Fig 1. If reading is not infinity, replace stator.
- On all models, connect ohmmeter leads to any stator lead and to stator frame. Ohmmeter reading should be infinity. See Fig 1.