Alternators - DELCO-REMY Transistor: Testing: Adjustment
- For an undercharged battery raise voltage setting by turning adjusting screw, remove access plug from regulator cover, clockwise one notch. Check for an improved battery condition after a service period of reasonable length and turn adjusting screw one additional notch clockwise if necessary.
NOTE:
After two notches there is a positive stop.
- For an overcharged battery, lower voltage setting by turning adjusting screw, counterclockwise one notch. Check for an improved battery condition after a service period of reasonable length and turn adjusting screw one more notch counterclockwise if necessary.
NOTE:
After two notches there is a positive stop.
Voltage Test Specifications
| Temperature |
Volts |
| 65°F |
14.1-14.9 |
| 85°F |
13.9-14.7 |
| 105°F |
13.7-14.5 |
| 125°F |
13.5-14.3 |
| 145°F |
13.4-14.2 |
Courtesy of GENERAL MOTORS COMPANY