LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Freightliner >> 2007 >> Sprinter 2500 V6-3.0L DSL Turbo >> Repair and Diagnosis >> Body and Frame >> Body Control Systems >> Body Control Module >> Diagrams >> Diagnostic Aids >> Troubleshooting Tests >> Testing Components For A Short To Ground On A Fuse Powering Several Loads
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Testing Components For A Short To Ground On A Fuse Powering Several Loads






TESTING COMPONENTS FOR A SHORT TO GROUND ON A FUSE POWERING SEVERAL LOADS
1. Refer to the wiring diagrams and disconnect or isolate all items on the suspected fused circuit.
2. Replace the blown fuse.
3. Supply power to the fuse by turning ON the ignition switch or re-connecting the battery.
4. Start connecting the items in the fused circuit one at a time. When the fuse blows the component with the short to ground has been isolated.