LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2008 >> Explorer 2WD V8-4.6L >> Repair and Diagnosis >> Heating and Air Conditioning >> Service and Repair >> Contaminated Refrigerant Handling
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Contaminated Refrigerant Handling

CONTAMINATED REFRIGERANT HANDLING

CAUTION: If contaminated refrigerant is detected, DO NOT recover the refrigerant into R-134a recovery/recycling equipment. Recovery of contaminated refrigerant will contaminate the recovered refrigerant supply and may damage the recovery/recycling equipment.

NOTE: A new suction accumulator or receiver/drier must be installed as directed by the A/C system flushing procedure.

1. Recover the contaminated refrigerant using suitable recovery-only equipment designed for capturing and storing contaminated refrigerant only.
- If this equipment is not available, contact an A/C service facility in your area with the correct equipment to carry out this service.

2. Determine and correct the cause of the customers initial concern.
3. Flush the A/C system.
4. Dispose of the contaminated refrigerant in accordance with all federal, state and local regulations.