LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2003 >> Taurus SES, 3.0 2, AX4S >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System - Generators & Regulators >> System Tests >> Test C: System Overcharges (More Than 15 Volts)
September 30: LEMON manuals is back up on a temporary server! Slowness is possible

Test C: System Overcharges (More Than 15 Volts)

  1. Connect New Generation Star (NGS) tester to Data Link Connector (DLC). Turn ignition on. Using NGS tester, perform Powertrain Control Module (PCM) self-test. If no DTCs are retrieved, go to next step. If any Diagnostic Trouble Codes (DTC) are retrieved, perform appropriate test in accordance with DTC retrieved. See appropriate SELF-DIAGNOSTICS article in ENGINE PERFORMANCE.
  2. Turn ignition off. Disconnect NGS tester. Start engine. With engine running and all accessories turned off, measure the voltage at battery while varying engine RPM. If the voltage is more than 15 volts, go to next step. If voltage is not more than 15 volts, go to step  4.
  3. Turn ignition off. Disconnect generator 3-pin connector. Turn ignition on. Measure voltage between ground and generator harness connector terminal No. 3 (Orange/Yellow wire). See Figure. If voltage is less than 0.5 volt from battery voltage, go to next step. If voltage is 0.5 volt or more from battery voltage, repair Orange/Yellow wire. See WIRING DIAGRAMS . After repair, clear DTCs and test system for normal operation.
  4. Turn ignition off. Connect generator 3-pin harness connector. Start engine. Check generator output. See GENERATOR LOAD TEST  and GENERATOR NO-LOAD TEST  under ON-VEHICLE TESTING. If generator is okay, system is operating correctly at this time. Check for corroded connections and check integrity of Orange/Yellow wire. If generator is not okay, install new generator. See GENERATOR  under REMOVAL & INSTALLATION. Clear the DTCs. Test the system for normal operation.