Electrical Specifications

Item Specification

Normal Engine Cranking Speed 140-220 rpm
Starter Motor Maximum Load 800 Amperes
Starter Motor Minimum Stall Torque (at 5 Volts) 14.7 Nm
Starter Motor No Load Current Draw 60-80 Amperes
Starter Motor Normal Load Current Draw 130-220 Amperes
Starting Circuit Maximum Voltage Drop (Engine Temperature Normal) 0.5 Volts