LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2003 >> Cutaway 7.3 F >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System - Generators & Regulators - Dual Generators >> Generator Specifications
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Generator Specifications

MOTORCRAFT GENERATOR SPECIFICATIONS

Application Specification
Generator Minimum Current Output
110-Amp Generator 87 Amps
Load Test
With Tester Load (1) 87 Amps Minimum
Without Tester Load (2) (3)
Pulley Ratio
Upper 2.49:1
Lower 2.32:1
No-Load Test (1) 13-15 Volts
(1) All accessories off with engine running at 2000 RPM.
(2) Perform this test with engine running at 2000 RPM, A/C on, blower motor on high speed, and headlamps on high beam.
(3) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.