LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1997 >> Crown Victoria Base, 4.6 9 >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes >> Drive Cycles >> EGR Monitor Repair Verification Drive Cycle
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

EGR Monitor Repair Verification Drive Cycle

    NOTE: Ambient air temperature or IAT PID must read a minimum of 32°F (0°C) to initiate the EGR monitor.
  1. Refer to and complete the vehicle check and preparation before initiating the following repair verification steps. See VEHICLE CHECK/PREPARATION .
  2. Start the engine and drive the vehicle for 6 minutes:
    • Drive in stop-and-go traffic for 5 minutes with at least 2 idle periods.
    • Accelerate to 45 MPH (72 km/h) at more than 1/2 throttle (35 MPH [56 km/h] on Escort/Tracer). Maintain speed for one minute.
  3. Rerun quick test. See QUICK TEST .