October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Manifold Absolute Pressure (Map) Sensor
MAP SENSOR FREQUENCY SPECIFICATIONS
| Manifold Vacuum (In. Hg) |
Frequency (Hz) |
| 0 |
159 |
| 3 |
150 |
| 6 |
141 |
| 9 |
133 |
| 12 |
125 |
| 15 |
117 |
| 18 |
109 |
| 21 |
102 |
| 24 |
95 |
| 27 |
88 |
| 30 |
80 |
MAP SENSOR VOLTAGE SPECIFICATIONS
| Elevation (Feet) |
Volts |
| 0 |
1.55-1.63 |
| 1000 |
1.52-1.60 |
| 2000 |
1.49-1.57 |
| 3000 |
1.46-1.54 |
| 4000 |
1.43-1.51 |
| 5000 |
1.40-1.48 |
| 6000 |
1.37-1.45 |
| 7000 |
1.35-1.43 |