LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1992 >> E 350 Van V8-7.3L DSL >> Repair and Diagnosis >> Starting and Charging >> Charging System >> Alternator >> Specifications >> Mechanical Specifications >> With Integral Regulator
September 30: LEMON manuals is back up on a temporary server! Slowness is possible

With Integral Regulator

Ford Make With Integral Regulator
<cf314009-010>
Slip Ring Turning - Minimum Diameter Slip Ring Turning - Maximum Runout Brush Length - New Brush Length - Wear Limit
Current Rating
Note: At 15 Volts
40 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
40 HE Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
60 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
65 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
75 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)
80 Ampere (A)1.22 Inch (in)0.0005 Inch (in)0.48 Inch (in)0.25 Inch (in)