Spring Lock Coupling Clamp Table: Installation

  1. Ensure replacement orifice tube is same color as that removed. Lubricate "O" rings on orifice tube with clean refrigeration oil. Place orifice tube into orifice tube remover/installer. Insert orifice tube into evaporator inlet tube until orifice tube bottoms against the stop.
  2. Remove orifice tube remover/installer. Install liquid on evaporator using a new "O" ring lubricated with refrigeration oil. Pull backward on liquid line to ensure proper seating of the line. Leak test, evacuate and recharge the system. Check system for proper operation.