LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1969 >> Bronco Base, Not Available, 2.8L Eng VIN F, Automatic Trans >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Ignition Systems - Solid State Ignition >> Testing >> Starting Circuit Test
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Starting Circuit Test

Voltage between pin #5 and engine ground with engine cranking should read between 8 and 12 volts. If reading not within limits, the ignition by-pass circuit is open or grounded from either the starter solenoid, the ignition switch to pin #5 or primary connections at the coil. Repair or replace as necessary.