July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!
High Temperature Vacuum Signal Modulator
OPERATION The modulator opens when the underhood air temperature reaches 115° F and causes a weakened vacuum signal to the EGR valve. As a result, the amount of exhaust gas being recirculated is decreased.