Charging System: Generator: Removal
- Disconnect the negative battery cable.
- Remove air cleaner assembly, refer to the AIR CLEANER HOUSING for more information.
- Remove the accessory drive belt, refer to COOLING for more information. See Fig 1.
- Disconnect the field connector. See Fig 2.
- Disconnect the battery positive cable from the generator first disconnect the B+ cap on the wiring harness side. See Fig 3.
- Remove the upper mounting bolt. See Fig 4.
- Remove the lower mounting bolt and nut. See Fig 4.
1 - Upper Mounting Bolt 2 - Lower Mounting Bolt - Remove generator. See Fig 5.