Charging System: Generator: Removal: 3.8L
- Disconnect negative battery cable.
- Remove the air box assembly, (Refer to ENGINE/AIR INTAKE SYSTEM/AIR CLEANER HOUSING - REMOVAL) - 2.5L or (Refer to ENGINE/AIR INTAKE SYSTEM/AIR CLEANER HOUSING - REMOVAL) - 3.8L .
- Generator location. See Fig 1.
1 - Connector Lock 2 - Field Connector - Unlock the field electrical connector. See Fig 2.
1 - Connector Lock 2 - Field Connector - Disconnect the field electrical connector from rear of generator. See Fig 3.
- Remove cover from battery cable on rear of generator. See Fig 4.
- Remove the positive battery cable from rear of generator.
- Remove the accessory drive belt. See Fig 5, (Refer to COOLING/ACCESSORY DRIVE/DRIVE BELTS - REMOVAL) .
- Remove the 3 mounting bolts for the power steering assembly. See Fig 6.
- Relocate the power steering assembly. See Fig 7.
- Remove the idler pulley/lower mounting bolt for generator. See Fig 8. This will be removed with generator assembly.
- Remove the rear mounting bolt. See Fig 9.
- Remove the upper mounting bolt. See Fig 10.
- Remove generator and idler pulley. See Fig 11.