LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chrysler >> 1998 >> Sebring V6-2.5L VIN N >> Repair and Diagnosis >> Starting and Charging >> Charging System >> Testing and Inspection >> Oscilloscope Patterns and Waveforms >> Standard Waveform
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Standard Waveform








NOTE: The voltage wave-form of the generator B terminal can undulate as shown in the small box. This wave-form is produced when the regulator operates according to fluctuations in the generator load (current), and is normal for the generator.
If the ripple height is extremely high (approx. 2 V or higher during idling), there is a disconnection between the generator B terminal and the battery due to a blown fuse, etc., and often the generator itself is normal.