Control Module HVAC: Service and Repair

Blower Motor Resistor and Power Module Replacement

REMOVAL

Negative Battery Cable Remote Terminal:




The Blower Motor Power Module is used on ATC systems only.
1. Open hood and disconnect the negative battery cable remote terminal from the remote battery post.
2. Remove lower right underpanel silencer/duct.
3. Disconnect wiring connectors on blower motor resistor.
4. Remove blower motor resistor retaining screws.
5. Pull blower motor resistor out of heater housing.

INSTALLATION
- For installation, reverse the above procedures.