Test 15A: Pump Motor Circuit Not Working Properly
NOTE:
Perform TEST 1A: CHECKING SYSTEM FOR DIAGNOSTIC TROUBLE CODES (DTCS)
before proceeding. For connector terminal ID, see CONNECTOR IDENTIFICATION
. For wiring diagram, see WIRING DIAGRAMS
.
- DTC may be caused by loose connections, open pump/motor or pump/motor relay wiring circuit, open CAB pump/motor monitor circuit, defective pump/motor, defective pump/motor relay or defective CAB. Go to next step.
- Turn ignition off, then on. Using scan tool, read DTCs. If scan tool displays VALVE POWER FEED CIRCUIT, perform TEST 20A: VALVE POWER FEED CIRCUIT . If scan tool does not display VALVE POWER FEED CIRCUIT, go to next step.
- Using scan tool, actuate pump/motor and listen for operating sound at pump/motor. If pump/motor operates, perform TEST 15B: PUMP MOTOR CIRCUIT NOT WORKING PROPERLY . If pump/motor does not operate, stop pump/motor actuation. Go to next step.
- Using scan tool in voltmeter mode, backprobe pump/motor relay connector terminal "D" (Dark Blue wire). See Figure
. If voltage is more than 10 volts, go to next step. If voltage is 10 volts or less, perform TEST 15C: PUMP MOTOR CIRCUIT NOT WORKING PROPERLY
.CAUTION: Ensure correct Brown/White wire is checked in following step as two Brown/White wires are used at pump/motor relay connector. Check voltage on pump/motor relay connector terminal "C".
- Using scan tool in voltmeter mode, backprobe pump/motor relay connector at terminal "C" (Brown/White wire). If voltage is more than 10 volts, go to next step. If voltage is 10 volts or less, repair open Brown/White wire between pump/motor relay and ABS main relay. Perform TEST VER-1A: VERIFICATION TEST .
- Using scan tool in voltmeter mode, backprobe pump/motor relay connector terminal "A" (Gray wire). If voltage is more than 10 volts, go to next step. If voltage is 10 volts or less, replace pump/motor relay. Perform TEST VER-1A: VERIFICATION TEST .
- Connect jumper wire between ground and pump/motor relay connector terminal "A" (Gray wire). Pump/motor relay should energize and pump/motor should operate. If pump/motor operates, disconnect jumper wire and perform TEST 15D: PUMP MOTOR CIRCUIT NOT WORKING PROPERLY
. If pump/motor does not operate, go to next step.CAUTION: Ensure correct Brown/White wire is checked in following step as two Brown/White wires are used at pump/motor relay connector. Check voltage on ABS main relay connector terminal "B". See Figure .
- Ensure jumper wire at terminal "A" is still installed. Using scan tool in voltmeter mode, backprobe pump/motor relay connector terminal "B" (Brown/White wire). If voltage is more than 10 volts, go to next step. If voltage is 10 volts or less, replace pump/motor relay. Perform TEST VER-1A: VERIFICATION TEST .
- Disconnect pump/motor connector. Using scan tool in voltmeter mode, check voltage on pump/motor connector terminal No. 2 (Brown/White wire). If voltage is more than 10 volts, go to next step. If voltage is 10 volts or less, repair open Brown/White wire between pump/motor relay and pump/motor. Perform TEST VER-1A: VERIFICATION TEST .
- Reconnect pump/motor connector. Ensure jumper wire at terminal "A" is still installed. Using scan tool in voltmeter mode, backprobe pump/motor connector terminal No. 1 (Black wire). If voltage is more than one volt, repair open Black wire. Perform TEST VER-1A: VERIFICATION TEST . If voltage is one volt or less, replace pump/motor. Perform TEST VER-1A.