Test 35D - One Door Fails To Lock & Unlock From Any SW
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For wiring diagrams, see WIRING DIAGRAMS
. Perform TEST VER-1 after each repair.
- Remove key from ignition switch. Remove appropriate door trim panel. Disconnect door lock motor connector. Using DRB in voltmeter mode, check voltage on door lock motor connector terminal No. 1 (Orange/Black wire). Depress door lock switch to LOCK position. If voltage is less than 10 volts, repair open Orange/Black wire. If voltage is more than 10 volts, go to next step.
- Check voltage on door lock motor connector terminal No. 2 (Pink/Black wire). If voltage is less than 10 volts, repair open Pink/Black wire. If voltage is more than 10 volts, replace door lock motor.