Circuit/System Description
For an overview of the component/system, refer to Door Ajar Indicator Description and Operation
| Circuit |
Description |
| Signal |
The control module input circuit has an internal resistance connected to 12 V. |
| Ground |
Chassis Ground |
| Component |
Description |
| A23 Door Latch Assembly |
The lock assemblies also contain a door ajar switch that is open when the door is closed. |
| M35D Window Motor Module - Driver |
- Power Window Control
- The control module also reads various switches and sensors and makes their values available via serial data.
|
| S79D Window Switch - Driver |
- Power Window Control
- The control module also reads various switches and sensors and makes their values available via serial data.
|
| S79P Window Switch - Passenger |
- Power Window Control
- The control module also reads various switches and sensors and makes their values available via serial data.
|
| S79LR Window Switch - Left Rear |
- Power Window Control
- The control module also reads various switches and sensors and makes their values available via serial data.
|
| S79RR Window Switch - Right Rear |
- Power Window Control
- The control module also reads various switches and sensors and makes their values available via serial data.
|