Installation Procedure (Battery, Charging System And Starting System)
- Install the generator to the bracket.
- Install the generator bolts and tighten to 50 N.m (37 lb ft).
- Install the generator cable to the generator, perform the following:
- Install the generator cable.
- Install the generator cable nut to the terminal stud and tighten to 9 N.m (80 lb in).
- Slide the boot over the terminal stud.
- Connect the generator electrical connector (3).
- Install the accessory drive belt. Refer to Drive Belt Replacement - Accessory .
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
CAUTION:
Refer to Fastener Caution .
Fig 3: Identifying Purge Solenoid Electrical Connector, Wiring Harness Nut & Generator Electrical Connector