Removal Procedure
- If equipped with a power sliding door, disable the PSD system by removing the PSD 15A fuse from the instrument panel (I/P) fuse block.
- Open the sliding door in order to gain access to the center roller bracket pin.
- Support the rear of the sliding door.
- Remove the pin (1) from the center roller bracket (2).
- Position the center roller bracket to the front radius of the sliding door center track.
- Release cable tension. Refer to Cable Tension Adjustment - Sliding Door .
- Remove the cables (1, 2) from the rear roller bracket (power sliding door only).
- Lift the center roller bracket (3) upwards and remove the bracket from the center track.
IMPORTANT:
By removing the power sliding door (PSD) 15A fuse, the low current logic power for both the LH and RH power sliding door modules (PSDM) will be interrupted and both PSDs will be inoperative.