Diagnostic Procedure
- Perform RKE system diagnostic system check. See REMOTE KEYLESS ENTRY SYSTEM DIAGNOSTIC SYSTEM CHECK under SELF-DIAGNOSTIC SYSTEM. If RKE system diagnostic system check has been performed, go to next step.
- Connect scan tool to Data Link Connector (DLC). Turn ignition switch to RUN position. Using scan tool, check status of DTC B3102. If DTC is current, go to next step. If DTC is not current, check for intermittent problem. See DIAGNOSING INTERMITTENTS . Repair or replace as necessary and go to step 9 .
- Turn ignition switch to OFF position. Disconnect RCDLR connector. See Figure . Measure voltage between RCDLR harness connector terminal No. 2 (Light Green wire) and ground. See Figure . Turn ignition switch to RUN position. If battery voltage is not present, go to next step. If battery voltage is present, go to step 5 .
- Check for short to ground in Light Green wire between RCDLR connector terminal No. 2 and BCM 24-pin, Pink connector C1 terminal A11. Repair as necessary and go to step 6 . See Figure and Figure . If problem was not found, go to step 9 .
- Check for poor connection at RCDLR connector. Repair as necessary and go to step 9 . If connection is okay, go to step 7 .
- Check for poor connection at BCM connectors. Repair as necessary and go to step 9 . If connection is okay, go to step 8 .
- Replace RCDLR. See REMOTE CONTROL DOOR LOCK RECEIVER under REMOVAL & INSTALLATION. Program and synchronize transmitters to new RCDLR. See RKE TRANSMITTER PROGRAMMING and TRANSMITTER SYNCHRONIZATION under PROGRAMMING. After repair, go to step 9 .
- Replace and program BCM. See BODY CONTROL MODULES - IMPALA & MONTE CARLO article. After repair, go to next step.
- Using scan tool, clear DTCs. Operate vehicle within CODE ENABLE CRITERIA conditions. Using scan tool, retrieve DTCs. If DTC B3102 resets, return to step 2 . If DTC B3102 does not reset, system is okay.
NOTE:
All RKE transmitters recognized by RCDLR must be programmed during programming sequence. If system is placed in program mode, it will erase all previously programmed RKE transmitters upon receipt of programming signal from first transmitter.