ZEXEL Rotary Vane
- Slowly discharge system using approved refrigerant recovery/recycling equipment. Remove A/C compressor. Install compressor oil drain Adapters (SA9149AC-5 and SA9149AC-6) to service ports. Drain compressor oil. Measure amount drained, and discard oil.
- Add proper amount of refrigerant oil to compressor (total system capacity minus amount retained in components that have not been replaced). See ZEXEL COMPONENT REFRIGERANT OIL CAPACITIES table. See REFRIGERANT OIL & REFRIGERANT CAPACITY tables in the A/C COMPRESSOR SERVICING article for total system capacity. Install compressor. Evacuate and recharge A/C system. Perform leak test.
ZEXEL COMPONENT REFRIGERANT OIL CAPACITIES
| Component | Ounces |
|---|---|
| Condenser | 1 |
| Evaporator | 3 |
| Receiver-Drier | 1 |