LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 1988 >> Seville Base >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> DFI ECM Tests W/Codes >> ECM Code EO31 - Shorted Map Sensor Circuit >> DFI ECM Tests W/Codes >> Notes On Intermittents
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Notes On Intermittents

Manipulate affected wiring and connectors while observing ECM parameter ED02. Apply and release vacuum to MAP sensor vacuum port using a vacuum source. If ECM parameter code ED02 displays greater than 105 kPa, condition has been induced and cause of intermittent should be repaired. If wiring and connectors are okay, substitute a known good sensor and retest.

Review snapshot data parameters stored with this code to verify failure. If failure is verified, check and repair intermittent wiring connection or sensor.

Fig 1: Schematic, Code EO31, Shorted MAP Sensor Circuit
G57295
Fig 2: Flow Chart, Code EO31, Shorted MAP Sensor Circuit
G57333
NOTE: If a hard code EO31 is accompanied by a hoard code EO38, See DFI Chart A, "Multiple ECM Codes Stored Hard".
Fig 3: Flow Chart, Code EO31, Shorted MAP Sensor Circuit
GB0048536