Circuit/System Verification
- Start the engine.
- Seal the EVAP system using the Purge/Seal function with a scan tool.
- Observe the FTP sensor with a scan tool. The Fuel Tank Pressure Sensor parameter should be within -1 to +1 inch H2O.
- If the Fuel Tank Pressure Sensor parameter is within -1 to +1 inch H2O, the condition is intermittent.