LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Buick >> 2005 >> Century Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 30 (HVAC Systems - Automatic) >> Repair Instructions >> Blower Motor Control Processor Replacement >> Removal Procedure
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Removal Procedure

WARNING: This page is about a different car, the 2004 Buick Regal and 2004 Buick Century. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove the right side IP insulator Panel. Refer to Closeout/Insulator Panel Replacement - Right in Instrument Panel, Gages and Console.
  2. Fig 1: View Of Electrical Connector For Blower Motor Control Processor
    GM295319Courtesy of GENERAL MOTORS CORP.
  3. Disconnect the electrical connector from the blower motor control processor.
  4. Fig 2: Blower Motor & Electrical Connector
    GM295327Courtesy of GENERAL MOTORS CORP.
  5. Disconnect the blower motor control processor electrical connector from the blower motor.
  6. Fig 3: View Of Blower Motor Control Processor
    GM295320Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: The opening to the blower motor control processor is slotted. Access to the blower motor control processor opening is limited.
  7. Loosen both of the forward bolts.
  8. Remove the rearward bolt.
  9. IMPORTANT: Tilt down the rear of the blower motor control processor.
  10. Remove the blower control processor.