Residual Air Check
System has valving arrangement to maintain residual pressure of 8-15 psi (14-20 psi on Eldorado, Riviera and Toronado) in shock absorbers. Test as follows:
- Attach air pressure gauge with tee fitting between dryer and air pressure line.
- Turn ignition "ON" to inflate shock absorbers.
- Turn ignition "OFF" and deflate through compressor service valve. Gauge should read 8-15 psi (14-20 psi on Eldorado, Riviera and Toronado) after system is deflated.