Diode Assembly

  1. Place DVOM on x100 scale. Connect DVOM leads, in turn, between B+ terminal and each of the 3 stator terminals. See Fig 1. Reverse leads. DVOM should indicate continuity in one direction only.
  2. Connect DVOM leads, in turn, between negative plate and each of the 3 stator terminals. Reverse leads. DVOM should indicate continuity in one direction only.
  3. Connect DVOM leads, in turn, between D+ terminal and each of the 3 stator terminals. Reverse leads. DVOM should indicate continuity in one direction only. Replace diode assembly if continuity is not as specified.
Fig 1: Testing Diode Assembly
G92C00564Courtesy of BMW OF NORTH AMERICA, INC.