September 30: LEMON manuals is back up on a temporary server! Slowness is possible
No Load Test
With starter on test bench, take readings of starter current, voltage and RPM. Readings should be within specifications.
STARTER NO LOAD TEST SPECIFICATIONS
| Model |
Volts/Amps. |
RPM |
| 208 xxx |
11.5/35-55 |
6000-8000 |
| 211 xxx |
11.5/30-50 |
6000-9000 |
| 212 xxx |
11.5/35-55 |
6000-8000 |
| 311 xxx |
11.5/30-50 |
5500-7500 |
| 312 xxx |
11/55-85 |
8500-10,500 |
| 317 xxx |
N/A |
N/A |
| 362 xxx |
11.5/65-95 |
6500-8500 |
BRUSH LENGTH & SPRING TENSION SPECIFICATIONS
| Application |
In. (mm) |
Ozs. (g) |
| 208 xxx |
.52 (13) |
40-50 (1150-1350) |
| 211 xxx |
.52 (13) |
40-46 (1150-1300) |
| 212 xxx |
N/A |
N/A |
| 311 xxx |
.52 (13) |
40-46 (1150-1300) |
| 312 xxx |
.39 (10) |
29-32 (800-900) |
| 314 xxx |
.52 (13) |
40-46 (1150-1300) |
| 317 xxx |
N/A |
N/A |
| 362 xxx |
.61 (15.5) |
40-46 (1150-1300) |