LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Audi >> 2007 >> S4 Quattro, 2D Convertible, Automatic >> Repair and Diagnosis >> Engine Performance >> Ignition System >> 4.2L - Generic Scan Tool, Engine Code(S): BHF >> Generic Scan Tool >> Diagnostic Trouble Code (DTC) tables >> SAE P2xxx-DTCs >> Transmission
September 30: LEMON manuals is back up on a temporary server! Slowness is possible

SAE P2xxx-DTCs: Transmission

DTC Error Message Diagnostic Procedure Malfunction Criteria and Threshold Value Secondary Parameters with Enable Conditions Monitoring Time Length Frequency of checks, MIL Illum
P2637 Torque management Feedback Signal A
  • Check DME Can-bus connection.
Detection of error signal
  • CAN bus, Active
  • ECU communication, Active
  • ECU data update, Active
250 ms
  • Continuous
  • 2 DCY
P2714 Pressure Control Solenoid D Performance or Stuck off PWM hardware detection, 0 or 100%
  • Low side and high side FET, Activated
  • Power supply, > 9 V
  • Volage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.03 Seconds
  • Continuous
  • 2 DCY
P2715 Pressure Control Solenoid D Stuck On PWM hardware detection, 0 or 100%
  • Low side and high side FET, Activated
  • Power supply, > 9 V
  • Volage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.03 Seconds
  • Continuous
  • 2 DCY
P2716 Pressure Control Solenoid D Electrical
  • Detection of wrong input AD value, Feedback current > 1333mA (AD value > 1000) for more than 100 msec
  • Detection of wrong input AD value, Feedback current 23mA (AD value 15) for more than 100 msec
  • Comparison of target current and Feedback current, Sum of difference of two current > 20000
  • Main solenoid switch, On
  • Linear feedback current, > 23 mA (AD:15) 1333 mA (AD:1000)
0.05 Seconds
  • Continuous
  • 2 DCY
P2723 Pressure Control Solenoid E Performance or Stuck off PWM hardware detection, 0 or 100%
  • Low side and high side FET, Activated
  • Power supply, > 9 V
  • Volage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2724 Pressure Control Solenoid E Stuck On PWM hardware detection, 0 or 100%
  • Low side and high side FET, Activated
  • Power supply, > 9 V
  • Volage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2725 Pressure Control Solenoid "E" Electrical
  • Detection of wrong input AD value, Feedback current > 1333mA (AD value > 1000) for more than 100 msec
  • Detection of wrong input AD value, Feedback current 23mA (AD value 15) for more than 100 msec
  • Comparison of target current and Feedback current, Sum of difference of two current > 20000
  • Main solenoid switch, On
  • Linear feedback current, > 23 mA (AD:15) 1333 mA (AD:1000)
0.05 Seconds
  • Continuous
  • 2 DCY
P2732 Pressure Control Solenoid F Performance or Stuck off PWM hardware detection, 0 or 100%
  • Low side and high side FET, Activated
  • Power supply, > 9 V
  • Volage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2733 Pressure Control Solenoid F Stuck On PWM hardware detection, 0 or 100%
  • Low side and high side FET, Activated
  • Power supply, > 9 V
  • Volage drop at FET, = 1 V
  • Solenoid supply, > 9 V
0.05 Seconds
  • Continuous
  • 2 DCY
P2734 Pressure Control Solenoid "F" Electrical
  • Detection of wrong input AD value, Feedback current > 1333mA (AD value > 1000) for more than 100 msec
  • Detection of wrong input AD value, Feedback current 23mA (AD value 15) for more than 100 msec
  • Comparison of target current and Feedback current, Sum of difference of two current > 20000
  • Main solenoid switch, On
  • Linear feedback current, > 23 mA (AD:15) 1333 mA (AD:1000)
0.05 Seconds
  • Continuous
  • 2 DCY