| P2637 |
Torque management Feedback Signal A |
- Check DME Can-bus connection.
|
Detection of error signal |
- CAN bus, Active
- ECU communication, Active
|
250 ms |
|
| P2714 |
Pressure Control Solenoid D Performance or Stuck off |
|
PWM hardware detection, 0 or 100% |
- Low side and high side FET, Activated
- Power supply, > 9 V
- Volage drop at FET, = 1 V
- Solenoid supply, > 9 V
|
0.03 Seconds |
|
| P2715 |
Pressure Control Solenoid D Stuck On |
|
PWM hardware detection, 0 or 100% |
- Low side and high side FET, Activated
- Power supply, > 9 V
- Volage drop at FET, = 1 V
- Solenoid supply, > 9 V
|
0.03 Seconds |
|
| P2716 |
Pressure Control Solenoid D Electrical |
|
- Detection of wrong input AD value, Feedback current > 1333mA (AD value > 1000) for more than 100 msec
- Detection of wrong input AD value, Feedback current 23mA (AD value 15) for more than 100 msec
- Comparison of target current and Feedback current, Sum of difference of two current > 20000
|
- Main solenoid switch, On
- Linear feedback current, > 23 mA (AD:15) 1333 mA (AD:1000)
|
0.05 Seconds |
|
| P2723 |
Pressure Control Solenoid E Performance or Stuck off |
|
PWM hardware detection, 0 or 100% |
- Low side and high side FET, Activated
- Power supply, > 9 V
- Volage drop at FET, = 1 V
- Solenoid supply, > 9 V
|
0.05 Seconds |
|
| P2724 |
Pressure Control Solenoid E Stuck On |
|
PWM hardware detection, 0 or 100% |
- Low side and high side FET, Activated
- Power supply, > 9 V
- Volage drop at FET, = 1 V
- Solenoid supply, > 9 V
|
0.05 Seconds |
|
| P2725 |
Pressure Control Solenoid "E" Electrical |
|
- Detection of wrong input AD value, Feedback current > 1333mA (AD value > 1000) for more than 100 msec
- Detection of wrong input AD value, Feedback current 23mA (AD value 15) for more than 100 msec
- Comparison of target current and Feedback current, Sum of difference of two current > 20000
|
- Main solenoid switch, On
- Linear feedback current, > 23 mA (AD:15) 1333 mA (AD:1000)
|
0.05 Seconds |
|
| P2732 |
Pressure Control Solenoid F Performance or Stuck off |
|
PWM hardware detection, 0 or 100% |
- Low side and high side FET, Activated
- Power supply, > 9 V
- Volage drop at FET, = 1 V
- Solenoid supply, > 9 V
|
0.05 Seconds |
|
| P2733 |
Pressure Control Solenoid F Stuck On |
|
PWM hardware detection, 0 or 100% |
- Low side and high side FET, Activated
- Power supply, > 9 V
- Volage drop at FET, = 1 V
- Solenoid supply, > 9 V
|
0.05 Seconds |
|
| P2734 |
Pressure Control Solenoid "F" Electrical |
|
- Detection of wrong input AD value, Feedback current > 1333mA (AD value > 1000) for more than 100 msec
- Detection of wrong input AD value, Feedback current 23mA (AD value 15) for more than 100 msec
- Comparison of target current and Feedback current, Sum of difference of two current > 20000
|
- Main solenoid switch, On
- Linear feedback current, > 23 mA (AD:15) 1333 mA (AD:1000)
|
0.05 Seconds |
|