LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2023 >> Stelvio Ti >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> DTC Index (3 Of 3) >> Module, Power Liftgate (PLGM)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Module, Power Liftgate (PLGM)

DIAGNOSTIC CODE INDEX

DTC Description
B188C-11 LIFTGATE CONTROL CIRCUIT 1 - SHORT TO GROUND
B188C-12 LIFTGATE CONTROL CIRCUIT 1 - SHORT TO BATTERY
B188C-13 LIFTGATE CONTROL CIRCUIT 1 - CIRCUIT OPEN
B188C-15 LIFTGATE CONTROL CIRCUIT 1 - SHORT TO BATTERY OR OPEN
B188C-19 LIFTGATE CONTROL CIRCUIT 1 - CIRCUIT CURRENT ABOVE THRESHOLD
B188C-31 LIFTGATE CONTROL CIRCUIT 1 - NO SIGNAL
B1890-11 LIFTGATE CONTROL CIRCUIT 2 - SHORT TO GROUND
B1890-12 LIFTGATE CONTROL CIRCUIT 2 - SHORT CIRCUIT TO BATTERY
B1890-13 LIFTGATE CONTROL CIRCUIT 2 - OPEN CIRCUIT
B1890-15 LIFTGATE CONTROL CIRCUIT 2 - SHORT CIRCUIT TO BATTERY OR OPEN
B1890-19 LIFTGATE CONTROL CIRCUIT 2 - CIRCUIT CURRENT ABOVE THRESHOLD
B1890-31 LIFTGATE CONTROL CIRCUIT 2 - NO SIGNAL
B1949-12 POWER LIFTGATE REAR ZONE SWITCH - CIRCUIT SHORT TO BATTERY
B1949 POWER LIFTGATE REAR ZONE SWITCH - STUCK
B1954 POWER LIFTGATE LATCH CINCH EXCESSIVE TIME - GENERAL SIGNAL FAILURE
B1954 POWER LIFTGATE LATCH CINCH EXCESSIVE TIME - NO OPERATION
B1968 POWER LIFTGATE OPEN DIRECTION EXCESSIVE TIME - PERFORMANCE OR INCORRECT OPERATION
B196B-92 POWER LIFTGATE CLOSE DIRECTION EXCESSIVE TIME - PERFORMANCE OR INCORRECT OPERATION
B197F-02 POWER LIFTGATE LATCH CONTROL 1 - GENERAL SIGNAL FAILURE
B197F-12 POWER LIFTGATE LATCH CONTROL 1 - CIRCUIT SHORT TO BATTERY
B2199 BATTERY VOLTAGE - CIRCUIT VOLTAGE BELOW THRESHOLD
B2199 BATTERY VOLTAGE - CIRCUIT VOLTAGE ABOVE THRESHOLD
B2199 BATTERY VOLTAGE - SIGNAL COMPARE FAILURE
B224E-44 POWER LIFTGATE MODULE INTERNAL - DATA MEMORY FAILURE
B224E-45 POWER LIFTGATE MODULE INTERNAL - PROGRAM MEMORY FAILURE
B224E-46 POWER LIFTGATE MODULE INTERNAL - CALIBRATION/PARAMETER MEMORY FAILURE
B224E-4B POWER LIFTGATE MODULE INTERNAL - OVER TEMPERATURE
B224E-54 POWER LIFTGATE MODULE INTERNAL - MISSING CALIBRATION
U0010 BH CAN - NO SIGNAL
U0010-88 BH CAN - BUS OFF
U0140 LOST COMMUNICATION WITH BODY CONTROL MODULE - MISSING MESSAGE
U0155 LOST COMMUNICATION WITH INSTRUMENT PANEL CLUSTER (IPC) CONTROL MODULE - MISSING MESSAGE