LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Alfa Romeo >> 2018 >> Stelvio Ti >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> Module, Power Liftgate (PLGM)
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Module, Power Liftgate (PLGM)

DIAGNOSTIC CODE INDEX

DTC Description
B188C-11 LIFTGATE CONTROL CIRCUIT 1-SHORT TO GROUND
B188C-12 LIFTGATE CONTROL CIRCUIT 1-SHORT TO BATTERY
B188C-13 LIFTGATE CONTROL CIRCUIT 1-CIRCUIT OPEN
B188C-15 LIFTGATE CONTROL CIRCUIT 1-SHORT TO BATTERY OR OPEN
B188C-19 LIFTGATE CONTROL CIRCUIT 1-CIRCUIT CURRENT ABOVE THRESHOLD
B188C-31 LIFTGATE CONTROL CIRCUIT 1-NO SIGNAL
B1890-11 LIFTGATE CONTROL CIRCUIT 2-SHORT TO GROUND
B1890-12 LIFTGATE CONTROL CIRCUIT 2-SHORT CIRCUIT TO BATTERY
B1890-13 LIFTGATE CONTROL CIRCUIT 2-OPEN CIRCUIT
B1890-15 LIFTGATE CONTROL CIRCUIT 2-SHORT CIRCUIT TO BATTERY OR OPEN
B1890-19 LIFTGATE CONTROL CIRCUIT 2-CIRCUIT CURRENT ABOVE THRESHOLD
B1890-31 LIFTGATE CONTROL CIRCUIT 2-NO SIGNAL
B1949-12 POWER LIFTGATE REAR ZONE SWITCH-CIRCUIT SHORT TO BATTERY
B1949-2A POWER LIFTGATE REAR ZONE SWITCH-STUCK
B1954-02 POWER LIFTGATE LATCH CINCH EXCESSIVE TIME-GENERAL SIGNAL FAILURE
B1954-93 POWER LIFTGATE LATCH CINCH EXCESSIVE TIME-NO OPERATION
B1968-92 POWER LIFTGATE OPEN DIRECTION EXCESSIVE TIME-PERFORMANCE OR INCORRECT OPERATION
B196B-92 POWER LIFTGATE CLOSE DIRECTION EXCESSIVE TIME-PERFORMANCE OR INCORRECT OPERATION
B197F-02 POWER LIFTGATE LATCH CONTROL 1-GENERAL SIGNAL FAILURE
B197F-12 POWER LIFTGATE LATCH CONTROL 1-CIRCUIT SHORT TO BATTERY
B2199-16 BATTERY VOLTAGE-CIRCUIT VOLTAGE BELOW THRESHOLD
B2199-17 BATTERY VOLTAGE-CIRCUIT VOLTAGE ABOVE THRESHOLD
B2199-62 BATTERY VOLTAGE-SIGNAL COMPARE FAILURE
B244E-44 POWER LIFTGATE MODULE INTERNAL-DATA MEMORY FAILURE
B224E-45 POWER LIFTGATE MODULE INTERNAL-PROGRAM MEMORY FAILURE
B24E-46 POWER LIFTGATE MODULE INTERNAL-CALIBRATION/PARAMETER MEMORY FAILURE
B24E-4B POWER LIFTGATE MODULE INTERNAL-OVER TEMPERATURE
B24E-54 POWER LIFTGATE MODULE INTERNAL-MISSING CALIBRATION
U0010-31 BH CAN-NO SIGNAL
U0010-88 BH CAN-BUS OFF
U0140-87 LOST COMMUNICATION WITH BODY CONTROL MODULE-MISSING MESSAGE
U0155-87 LOST COMMUNICATION WITH INSTRUMENT PANEL CLUSTER (IPC) CONTROL MODULE-MISSING MESSAGE