Engine Electrical Service Specifications
| Item | Measurement | Qualification | Standard or New | Service Limit |
|---|---|---|---|---|
| Ignition coil | Firing order | - | 1-3-4-2 | |
| Spark plug | Gap | - | 0.70-0.75 mm (0.0276-0.0295 in) | - |
| Ignition timing | At idle Check the red mark | In N or P | 2+/-2 deg. ATDC (conversion value by HDS: -2+/-2 deg.) | |
| Drive belt | Tension | - | Auto-tensioner | |
| Alternator | Brush length | - | 10.5 mm (0.413 in) | 1.5 mm (0.059 in) |
| Starter | Commutator mica depth | - | 0.40-0.50 mm (0.0157-0.0197 in) | 0.15 mm (0.0059 in) |
| Commutator runout | - | 0.02 mm (0.0008 in) max. | 0.05 mm (0.0020 in) | |
| Commutator O.D. | - | 28.0-28.1 mm (1.102-1.106 in) | 27.5 mm (1.083 in) | |
| Brush length | - | 11.1-11.5 mm (0.437-0.453 in) | 4.3 mm (0.169 in) | |