LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Acura >> 2012 >> RL >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control >> Rear Vent Control Motor Test
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Rear Vent Control Motor Test

NOTE: Before testing, check for climate control DTCs (see HOW TO CHECK FOR DTCS WITH THE HDS  ).
  1. Disconnect the 5P connector from the rear vent control motor.
    NOTE: Incorrectly applying power and ground to the rear vent control motor will damage it. Follow the instructions carefully.
  2. Connect battery power to terminal No. 1 of the rear vent control motor, and ground terminal No. 2; the rear vent control motor should run smoothly, and stop at Shut. If it does not, reverse the connections; the rear vent control motor should run smoothly, and stop at Rear Vent. When the rear vent control motor stops running, disconnect battery power immediately.
    Fig 1: Identifying Rear Vent Control Motor Connector
    G07354738Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. If the rear vent control motor did not run in step  2, remove it, then check the rear vent control linkage and the door for smooth movement.