September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Recirculation Control Motor Replacement
- Remove the evaporator (see EVAPORATOR REMOVAL AND INSTALLATION ).
- Disconnect the 5P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the blower unit.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Install the motor in the reverse order of removal. After installation, make sure the recirculation control motor runs smoothly.